HS Series Data Sheets: (by package and supply voltages)
| Package Photo |
Product Series
(pdf) |
Supply
Voltage |
Freq. min.(MHz) |
Freq. max.(MHz) |
No. of pins or pads |
Package Size (mm) / Description / Features |
 |
3HS14 |
3.3 V |
10 |
800 |
4 |
Full Size 4 pin DIP, 50 Ω load with output ≥ 0 dBm |
| 5HS14 |
5 V |
10 |
156 |
4 |
Full Size 4 pin DIP, 50 Ω load with output ≥ 0 dBm |
 |
3HS24 |
3.3 V |
10 |
800 |
4 |
Full Size 4 pin gull wing, 50 Ω load with output ≥ 0 dBm |
| 5HS24 |
5 V |
10 |
156 |
4 |
Full Size 4 pin gull wing, 50 Ω load with output ≥ 0 dBm |
General Specifications:
TA=+25°C, VDD= at specified voltage, Load: 10 KΩ // 10 pF
|
3.3 V System |
5.0 V System |
| Input Voltage (VDD) |
VDD = +3.3 V D.C. ±5%
Voltage Code is "3" |
VDD = +5.0 V D.C. ±5%
Voltage Code is "5" |
| Frequency Range |
10 MHz ~ 800 MHz |
10 MHz ~ 156 MHz |
| Frequency Stability(1) |
Commercial Temperature
(0C to +70C)
code is "C" |
Stability Code "A": ±25 ppm over 0°C to +70°C
Stability Code "B": ±50 ppm over 0°C to +70°C
Stability Code "C": ±100 ppm over 0°C to +70°C
If non-standard please enter the desired stability after the "C"
(e.g. C20 represents ±20 ppm over 0°C to +70°C) |
Industrial Temperature
(-40C to +85C)
code is "I" |
Stability Code "D": ±25 ppm over -40°C to +85°C
Stability Code "E": ±50 ppm over -40°C to +85°C
Stability Code "F": ±100 ppm over -40°C to +85°C
If non-standard please enter the desired stability after the "C"
(e.g. I20 represents ±20 ppm over -40°C to +85°C) |
| Output Level |
0 dBm min. into 50 Ω, output power up to 5 dBm is also available |
| Harmonics |
-20 dBc max. |
| Phase Noise |
-140 dBc at 10 KHz Offset |
| Sub-harmonic |
None |
| Current Consumption |
10 MHz: 9 mA typical
100 MHz: 18 mA typical
150 MHz: 19 mA typical |
10 MHz: 18 mA typical
100 MHz: 34 mA typical
150 MHz: 36 mA typical |
| Option on Pin 1 |
Output is high impedance when pin 1 is taken low.
Disable time is150 n sec max.
Please add "T" after the stability code for this option. |
| Storage Temperature |
-50°C to +100°C |
| Aging |
±5 ppm per year max. |
(1)Inclusive of 25°C tolerance, operating temperature range, ±10% input voltage variation, load change, aging, shock and vibration. |