3.3 V System |
5.0 V System |
| Input Voltage (VDD) |
VDD = +3.3 V D.C. ±5%
Voltage code is "3" |
VDD =+5.0 V D.C.±5%
Voltage code is "5" |
| Frequency Range |
1 MHz ~ 156 MHz |
1 MHz ~ 156 MHz |
| Control Voltage Center |
+1.65 V DC ±0.25 V |
+2.5 V DC ±0.5 V |
| Initial Frequency Accuracy (at+25°C) |
±15 ppm when control voltage is set at +1.65 V DC |
±15 ppm when control voltage is set at +2.5 V DC |
| Control Voltage Range |
+0.3 V to +3.0 V D.C. |
+0.5 V to +4.5 V D.C. |
| Frequency Deviation Range |
±80 ppm typical. Wider pulling range available |
±100 ppm typical. Wider pulling range available |
Frequency Stability(1)
|
Commercial Temp.
Range (code "C") |
"A": ±25 ppm over 0°C to +70°C
"B":±50 ppm over 0°C to +70°C
"C":±100 ppm over 0°C to +70°C
For non-standard please give desired frequency stability after the "C".
For example "C20" is ±20 ppm over 0 to +70°C |
Frequency Stability(1)
|
Industrial Temp.
Range (code "I") |
"D":±25 ppm over -40°C to +85° (not available on all packages)
"E":±50 ppm over -40°C to +85°C
"F":±100 ppm over -40°C to +85°C
For non-standard please give desired frequency stability after the "I".
For example "I20" is ±20 ppm over -40 to +85°C |
| Output Level |
0 dBm min. into 50 ohms. Output power up to 5 dBm is also available. |
| Harmonics |
< -20 dBc |
| Current Consumption |
10 MHz: 9 mA typical
100 MHz: 18 mA typical
150 MHz: 19 mA typical |
10 MHz: 18 mA typical
100 MHz: 34 mA typical
150 MHz: 36 mA typical |
| Linearity |
±10 % max. |
| Slope Polarity (Transfer Function) |
Monotonic and Positive: Increasing control voltage always increases output frequency. Negative slope is also available. |
| Input Impedance |
10 kΩ at 10 kHz min. |
| Frequency Response |
10 KHz min |
| 3 dB modulation Bandwidth |
10 KHz min. |
| Storage Temperature |
-50°C to +100°C |
| Aging |
±5 ppm per year max. |
(1)Inclusive of 25°C tolerance, operating temperature range, ±10% input voltage variation, load change, aging, shock and vibration.